Fluke 101 Digital Multimeter designed for simple electric tests, the Fluke hundred and virtual multimeters give dependable measurements for residential/business electricians and heating and air-con technicians. This small, lightweight multimeter suit is simply on your hand however is rugged sufficient to resist everyday use for years to come. When it involves professional-grade less expensive multimeters, the Fluke a hundred and virtual multimeters is your first-rate choice.
Specifications: Fluke 101 Digital Multimeter
Electrical Specifications |
V AC (40-500Hz) |
Range |
600.0 mV 6.000 V 60.00 V 600.0 V |
Resolution |
0.1 mV 0.001 V 0.01 V 0.1 V |
Accuracy |
3.0%±3 digit 1.0%±3 digit |
V DC |
Range |
6.000 V 60.00 V 600.0 V |
Resolution |
0.001 V 0.01 V 0.1 V |
Accuracy |
0.5%±3 digit |
Resistance Ohms |
Range |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
Resolution |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy |
0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit |
Capacitance |
Range |
50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000.0 μF |
Resolution |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
Frequency (10 Hz – 100 kHz) |
Range |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
Resolution |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
Duty Cycle |
Range |
0.1 % to 99.9 % |
Resolution |
0.1 % |
General Specifications |
CAT Rating |
CAT III 600 V |
V AC Range |
600.0 V |
V DC Range |
600.0 V |
Ohms Range |
40.00 MΩ |
Auto Shutoff |
Y |
Continuity |
Y |
Capacitor |
100.0 μF |
Frequency |
100.0 kHz |
Hold |
No |
Duty Cycle |
Yes |
Size |
130 mm x 65 mm x 27mm |
Weight |
160 g |
Battery |
Two AAA |
Warranty |
1 year |
Environmental Specifications |
Operating Temperature |
0 °C to +40 °C |
Storage Temperature |
-30 °C to +60 °C |
Operating Humidity |
Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without Condensation) |
Operating Humidity, 40 MΩ |
80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C |
Operating Altitude |
2,000 meters |
Storage Altitude |
12,000 meters |
IP Rating |
IP 40 per IEC 60529 |
Vibration Requirements |
MIL-PRF-28800F, Class 2 |
Drop Test Requirements |
-10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. |
EMI, RFI, EMC |
Must meet all applicable requirements in IEC/EN 61326-1 |
Absorption/Corrosion |
Per Fluke SOP 39.1 |
Temperature Coefficients |
Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC |