Fluke 106 Palm-sized Digital Multimeter usually offers a correct and dependable end result. The display screen and controls are well portioned and, no matter being Chinese-made, it has the coolest construct great and class ratings.
Fluke 106 Palm-sized Digital Multimeter now no longer the most effective and offers a nice end result however the fee of this meter is usually spot on. The primary matter approximately Fluke 106 virtual multimeter usually offers a correct and dependable bring about any environment. We provide a nice Fluke multimeter for you with unfastened transport everywhere in Bangladesh via Unique Tools BD.
Specifications: Fluke 106 Palm-sized Digital Multimeter
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Accuracy Specifications |
Function |
Range |
Resolution |
Accuracy |
AC Volts (40 Hz to 500Hz)1 |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 |
DC Volts |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 |
AC Millivolts |
600.0 mV |
0.1 mV |
3.0 % + 3 |
Diode Test2 |
2.000 V |
0.001 V |
10 % |
Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
Capacitance3 |
50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA |
Duty Cycle4 |
1 % to 99 % |
0.1 % |
NA |
AC Current (40 Hz to 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
DC Current |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
- All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
- Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
- Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
- All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
|
Function |
Overload Protection |
Input Impedance (Nominal) |
Common Mode Rejection Ratio |
Normal Mode Rejection Ratio |
AC Volts |
600 V 1 |
>10 MΩ <100 pF 2 |
>60 dB at dc, 50 Hz or 60 Hz |
− |
\AC Millivolts |
600 mV |
>1M, <100 pF |
>80 dB at 50 Hz or 60 Hz |
− |
DC Volts |
600 V 1 |
>10 MΩ <100 pF |
>100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
- 6 x 105 V Hz Max
- For mV (AC), input impedance is approximately 1 MΩ.
|
General Specifications |
Maximum Voltage Between any Terminal and Earth Ground |
600 V |
Display (LCD) |
6000 counts, updates 3/sec |
Battery Type |
2 AAA, NEDA 24A, IEC LR03 |
Battery Life |
200 hours minimum |
Temperature |
Operating |
0 °C to 40 °C |
Storage |
-30 °C to 60 °C |
Relative Humidity |
Operating Humidity |
Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C |
Operating Humidity, 40 MΩ Range |
≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C |
Altitude |
Operating |
2000 m |
Storage |
12,000 m |
Temperature Coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Fuse Protection for Current Inputs |
11A, 1000V Fast Fuse, Fluke specified part only |
Size (HxWxL) |
142 mm x 69 mm x 28mm |
Weight |
200 g |
IP Rating |
IEC 60529: IP 40 |
Safety |
IEC 61010-1: 600 V CAT III, Pollution Degree 2 |
Electromagnetic Environment |
IEC 61326-1: Portable |
Electromagnetic Compatibility |
Applies to use Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1 |
- This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
|