Fluke 113 Digital Multimeter basically a general-purpose, `utility` multimeter. Fluke 113 Digital Multimeter is greater than user-pleasant for trainees, specialists, and people which have a hands-on job.
Fluke 113 Multimeter Has Safety ratings: CAT-III to 600V, CAT-IV to 300V with a Large backlit display. This present-day multimeter now no longer simplest offers a correct and dependable end result however additionally the price of this meter is usually spot on.
We provide satisfactory products thru Tools Bangladesh the most important e-trade web page in Bangladesh provides satisfactory & cheap Digital multimeters for our customers. Keep it easy and get the satisfactory Fluke 113 virtual multimeter from Unique Tools BD.
Specification: Fluke 113 Digital Multimeter
Specifications |
VCHEK1 2 3 |
Range |
6.000 V / 60.00 V / 600.0 V |
Resolution |
0.001 V / 0.01 V/ 0.1 V |
Accuracy |
DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3 |
Diode test4 |
Range |
2.000 V |
Resolution |
0.001 V |
Accuracy |
2.0% + 3 |
Continuity4 |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ω4 |
Range |
600.0 Ω / 6.000 kΩ / 60.00 kΩ |
Resolution |
0.1 Ω / 0.001 kΩ / 0.01 kΩ |
Accuracy |
0.9% + 2 / 0.9% + 1 / 0.9% + 1 |
Capacitance4 |
Range |
1000 nF / 10.00 μF / 100.0 μF / 9999 μF |
Resolution |
1 nF / 0.01 μF / 0.1 μF / 1 μF |
Accuracy |
1.9% + 2 100 μF - 1000 μF: 1.9% + 2 1000 μF: 5% + 20 |
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. |
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Display |
3 3/4-digits, 6000 counts, updates 4/sec |
Operating temperature |
-10°C to 50°C (14°F to 122°F) |
Storage temperature |
-40°C to 60°C (-22°F to 140°F) |
Temperature coefficient |
0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
Operating altitude |
2,000 m |
Storage altitude |
10,000 m |
Relative humidity |
95% to 30°C 75% to 40°C 45% to 50°C |
Battery type |
9 Volt Alkaline, ANSI 1604A / IEC 6F22 |
Battery life |
Alkaline: 300 hours typical, without backlight |
Shock |
1 Meter drop per IEC 61010–1–2001 |
Vibration |
Per MIL-PRF-28800 for Class 2 instrument |
Size (H x W x L) |
167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) |
Weight |
13.0 oz (404 g) |
Safety |
Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1 |
EMI regulations |
Complies with FCC Part 15, Class B |
Specifications |
VCHEK |
Input impedance (nominal) |
~3 kΩ < 300 pF |
VCHEK |
Common mode rejection ratio (1 kΩ unbalanced) |
> 60 dB at DC, 50 or 60 Hz |
Ω |
Open circuit test voltage |
< 2.7 VDC |
Full scale voltage |
< 0.7 VDC |
Diode test |
Open circuit test voltage |
2.7 VDC |
Full scale voltage |
2.000 VDC |
Ω |
Short circuit current |
< 350 μA |
Diode test |
Short circuit current |
< 1.0 mA |