Model: Fluke 114 Electrical Multimeter
The Fluke 114 Electrical Multimeter has a pleasing backlit display screen and construct quality, and may carry out correct measurements of numerous AC pressure outputs. Having simply the basics – voltage, resistance, and continuity – and one-surpassed operation make it mainly beneficial for beginners.
The Fluke 114 plays nicely enough, with a brief continuity checker and great guide ranging. The variety transfer has devoted ranges, in large part because of the shortage of functions. The handiest time you want to hit the pick-out button is while measuring DC millivolts. Order the fluke 114 Multimeter, Unique Tools BD we are able to supply to your doorstep. Get the best one from Unique Tools BD.
Key Features: Fluke 114 Electrical Multimeter
- Ideal Digital Multimeter for “go/no-go” testing
- Features AutoVolt automatic AC/DC voltage selection
- Provides Min/Max/Average with elapsed time to record signal fluctuations
- Measures resistance, continuity, frequency, and capacitance
- Includes low input impedance to help prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
Specifications: Fluke 114 Electrical Multimeter
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10°C to + 50°C |
Storage temperature |
-40°C to + 60°C |
Battery type |
9 volt Alkaline, NEDA 1604A / IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy specifications |
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/resolution |
6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9% + 1 |
Range/resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5% + 2 |
1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc-coupled, 45 Hz to 5 kHz for ac current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight |
550 g |
Warranty |