Model: Fluke 1502A Tweener Thermometer Readouts
Fluke 1502A Tweener Thermometer ReadoutsOne of Fluke Calibration's best-selling products is the Tweener thermometer, and there’s a reason. No other company, not one, has a reference thermometer that comes close to the performance and features of the Tweener for anywhere near its price.
The best things about Tweener Thermometer Readouts that not only always provide accurate results but also the value of this Fluke product always spot on.
We Iconic Engineering offers the best and reliable Tweener Thermometer Readouts through Tools Bangladesh with affordable price. Keep it and get the best product that you are always looking for.
Specifications: 1502A, 1504 Tweener Thermometer Readouts
Specifications
|
1502A |
1504 |
Temperature Range† |
−200 °C to 962 °C (−328 °F to 1764 °F) |
Any thermistor range |
Resistance Range |
0 Ω to 400 Ω, auto-ranging |
0 Ω to 1 MΩ, auto-ranging |
Probe |
Nominal RTPW: 10 Ω to 100 Ω RTD, PRT, or SPRT |
Thermistors |
Characterizations |
ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 IPTS-68: R0, a, d, a4, and c4 Callendar-Van Dusen: R0, a, d, and b |
Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b |
Resistance Accuracy (ppm of reading) |
0 Ω to 20 Ω: 0.0005 Ω 20 Ω to 400 Ω: 25 ppm |
0 Ω to 5 KΩ: 0.5 Ω 5 KΩ to 200 KΩ: 100 ppm 200 KΩ to 1 MΩ: 300 ppm |
Temperature Accuracy† |
±0.004 °C at −100 °C ±0.006 °C at 0 °C ±0.009 °C at 100 °C ±0.012 °C at 200 °C ±0.018 °C at 400 °C ±0.024 °C at 600 °C |
±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.) |
Operating Temperature Range |
16 °C to 30 °C |
13 °C to 33 °C |
Resistance Resolution |
0 Ω to 20 Ω: 0.0001 Ω 20 Ω to 400 Ω: 0.001 Ω |
0 Ω to 10 KΩ: 0.01 Ω 10 KΩ to 100 KΩ: 0.1 Ω 100 KΩ to 1 MΩ: 1 Ω |
Temperature Resolution |
0.001 °C |
0.0001 °C |
Excitation Current |
0.5 and 1 mA, user selectable, 2 Hz |
2 and 10 µA, automatically selected |
Measurement Period |
1 second |
Digital Filter |
Exponential, 0 to 60 seconds time constant (user selectable) |
Probe Connection |
4-wire with shield, 5-pin DIN connector |
Communications |
RS-232 serial standard IEEE-488 (GPIB) optional |
Display |
8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters |
Power |
115 VAC (±10 %), 50/60 Hz, 1 A, nominal 230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify |
Size (HxWxD) |
61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) |
Weight |
1.0 kg (2.2 lb.) |
Probes from Fluke Calibration |
5615, 5627, 5626, 5628, 5622 |
5640-44, 5610-65 |
Calibration |
ISO 17025-accredited calibration provided |
†Temperature ranges and accuracy may be limited by the sensor you use. |